Micropilot FMR54 is prepared for the use in high temperature and high pressure applications and with the specially designed planar antenna it is particularly suited for stilling well applications. The FMR54 free space radar is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Horn antenna or planar antenna which is particularly suited for stilling well applications.
Kemira, a global chemicals company, needs accurate monitoring of level and temperature for polymer manufacturing. They use instrumentation with Bluetooth for safe and easy access to process data.
Protolaunch bruker strømningsmålere og nivåsensorer fra Endress+Hauser ved et testanlegg for rakettpropulsjon i Buckinghamshire for å demonstrere ytelsen til propulsjonssystemene og komponentene.
Global crop protection and seed technology company Nufarm reduces measurement uncertainty to less than 1% with new-generation 80 GHz radar level sensors
Continuous non-contact level measurement for use in high-pressure and high-temperature applications, Horn or planar antenna
Specialities
Heartbeat Technology, SIL 2 according to IEC 61508, Bluetooth® commissioning, Operation and maintenance SmartBlue App, Safety and reliability with Multi-Echo Tracking, HistoROM, RFID TAG for easy identification
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional)
Frequency
C-band (~6 GHz)
Accuracy
+/- 6 mm (0.24 in)
Ambient temperature
-50...+80 °C (-58...+176 °F)
Process temperature
-60...+400°C (-76...+752°F)
Process pressure / max. overpressure limit
Vacuum...160 bar (Vacuum...2320 psi)
Main wetted parts
316L
Process connection
Flange: DN80...DN300, ASME 3"...12", JIS 10K, 20K
Max. measurement distance
Standard: 20 m (65 ft) Planar antenna in stilling well: 38 m (125 ft)
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, JPN Ex, INMETRO, NEPSI, KC, EAC, UK Ex
Safety approvals
Overfill protection WHG SIL
Design approvals
EN 10204-3.1 NACE MR0175, MR0103 ASME B31.3 AD2000
Marine approval
GL/ ABS/ LR/ BV/ DNV
Options
Display, Customized parameterization, Remote operation via SmartBlue App using Bluetooth®, PWIS free, Gastight feed through
Application limits
Maximum measuring range is dependent on the tank form and/or application Free space with nozzle: FMR51, FMR52, FMR53 Stilling well with ball valve: FMR51, FMR52 Hygiene requirements: FMR52, FMR53 316L or Alloy C non-resistant: FMR52, FMR53
RN42 er en 1‑kanals aktiv barriere for 4–20 mA, HART®‑transparent, med bred forsyningsspenning (24–230 V AC/DC) og fleksibel aktiv/passiv inngang og utgang. Leveres valgfritt med SIL‑ og Ex‑godkjenning.
Sløyfedrevet prosessindikator for 4–20 mA og HART®. Kompakt, robust og ideell for lokal visning i felt- og panelmontasje, med klart 5 sifret LCD display (17 mm)
RN42 er en 1‑kanals aktiv barriere for 4–20 mA, HART®‑transparent, med bred forsyningsspenning (24–230 V AC/DC) og fleksibel aktiv/passiv inngang og utgang. Leveres valgfritt med SIL‑ og Ex‑godkjenning.
Sløyfedrevet prosessindikator for 4–20 mA og HART®. Kompakt, robust og ideell for lokal visning i felt- og panelmontasje, med klart 5 sifret LCD display (17 mm)
Vi bruker informasjonskapsler til å forbedre surfeopplevelsen din, samle inn statistikk for å optimalisere nettstedsfunksjonalitet og vise skreddersydde annonser eller skreddersydd innhold.