FLOWSIC100 was designed for emission monitoring tasks. The "H" versions are suitable for stacks with large diameters and applications with high dust content. The ultrasonic transducers of the "PR" probe type are mounted with fixed path length on one sender/receiver unit (measuring probe). The "AC" versions have an innovative internal cooling and are suitable for gas temperatures up to 450 °C. The purged "Px" versions are used for gases with high concentrations of sticky or wet dust.
Emission monitoring in the chemical and hydrocarbon processing (HPI) industry
Emission measurement in the processing industry (cement, iron and steel, glass)
Device properties:
Rugged titanium converters for long service life
Corrosion-resistant material for use with aggressive gases (option)
Integrated measurement via duct diameter for types H, M, and S
Probe version PR for cost-saving, single-sided installation in duct
Automated operational check with zero and reference point test
Fordeler
Reliable flow measurement for ducts with small up to very large diameters
No purge air required for applications with gas temperatures up to 260 °C
Minimum operating and maintenance costs
Accurate measuring results under difficult measuring conditions
Measurement without pressure loss, therefore no influences on the process
Schluchseewerk AG ønsket å registrere og optimalisere effektiviteten til turbinene sine ved pumpekraftverket i Wehr. Endress+Hauser tilbyr den optimale løsningen med sin ultrasoniske clamp-on-strømningsmåler.
GPsol har, sammen med Endress+Hauser, utviklet et system som måler hver enkelt komponent i utvinningsbrønner og gir så mye informasjon som mulig om den nåværende strømningen.
På den nye fabrikkalibreringsriggen fra Endress+Hauser kan Wintershall Dea nå kalibrere Promass F med hydrokarboner i henhold til loven – et vesentlig billigere alternativ enn kalibrering på stedet.
Volumetric flow a. c., volumetric flow s. c., gas velocity, sound velocity, gas temperature
Measuring range
Gas Velocity: 0 ... ± 40 m/s
Medium temperature range
–40 °C ... +260 °C
Operating pressure range
–100 hPa ... 100 hPa
Nominal pipe size
0,15 ... 13m
Conformities
2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV 30. BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 EN 16911-2 MCERTS GOST
Outputs
1 output: 0/2/4 ... 20 mA, + 750 Ω Electrically isolated, up to five outputs when add-on modules are used (option)
Digital Outputs
5 relay outputs (change-over contacts), potential-free: + 48 V, 1 A Safety extra-low voltage; for status signals "operation/malfunction", "limit value", "warning", "maintenance" and "check cycle"
With our broad range of solutions Endress+Hauser has proven applicability in the entire power generation process, from gas flow to combustion efficiency to emissions monitoring.
Emission Monitoring Solutions – broad instrument portfolio and
longstanding experience
Kompetansebrosjyre (CP)
Engelsk versjon - 01/2025
New version available in English
An overview brochure about emission monitoring, their measuring principles and technologies, global requirements and services, a selection guide and the measuring devices at a glance
Fortsett for å velge blant alle mulige alternativer
Vi verdsetter personvernet ditt
Vi bruker informasjonskapsler til å forbedre surfeopplevelsen din, samle inn statistikk for å optimalisere nettstedsfunksjonalitet og vise skreddersydde annonser eller skreddersydd innhold.