TLSR5
South African style temperature assembly

TLSR5
South African style temperature assembly ©Endress+Hauser

Comprehensive and common temperature measurement technology for almost all branches of industry

The thermometer is mainly used in the chemical industry but also finds its use in other branches. The device with head transmitter is a complete unit ready for use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections and dimensions offer flexible application possibilities.

  • Fordeler

    • Pt100 measuring element according to IEC 60751 with an accuracy Class A according to IEC 60751 and Band 5 (1/10 DIN)

    • Sheath material SS316/L

    • Customized immersion length

    • Electrical connection by means of a ceramic terminal block or head mounted transmitter...

  • Bruksområde

    RTD sensor for industrial applications. The thermometer consists of a 6 mm diameter stem with either a transmitter mounting plate or a ceramic terminal block. The terminal head can be selected from a wide choice of standard items.

    It also provides an...

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Resistance Temperature Detector

  • Characteristic / Application

    S.A. Style

    universal range of application

    usable with or without a thermowell

    spring loaded for use in thermowell

    Options available to construct removable inserts (spare parts)

  • Terminal head

    wide range of heads possible

    possible materials of construction: PVC, aluminium, SS316

    mixed output options possible

  • Thermowell / protection tube

    to use with or without thermowell (can be ordered separately)

  • Insert / probe

    mineral insulated (MI), flexible

  • Max. immersion length on request

    up to 2.000 mm (78,74'')

  • Material protection tube/ thermowell

    1.4401 (316)

  • Optional coating

    Not defined

  • Process connection

    Fixed thread:

    NPT 1/4"

    NPT 1/2"

    G1/4"

    G1/2"

    Union nipple:

    NPT 1/2"

    G1/2"

  • Tip shape

    rounded

    flat

  • Operating temperature range

    PT 100:

    -200 ...600 °C

    (-328 ...1.112 °F)

  • Max. process pressure (static)

    at 20 °C: 10 bar (150 psi) without thermowell

  • Accuracy

    class A acc. to IEC 60751

    Band 5 (1/10 DIN)

  • Response time

    depending on configuration

  • Integration head transmitter

    yes (4 ... 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)

  • Certification

    EN10204 3.1 Material traceability

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification
    • Order code 71044061

      Fixing kit cpl.TMT82/85/84 (european)

      2x screws, 2x springs, 2x spring rings, 1x sealing CDI-connector

    • Order code READWIN-

      Readwin 2000 Operation + Read. software

    • Order code TXU10-

      Configuration kit TXU10-

      for PC-programmable devices. set-up programme+interface cable for PC with USB-Port.

  • B
    • Nr B Order code TMT180-

      iTEMP TMT180, Head Transmitter Pt100

      Temperature transmitter,PC-programable. Application: RTD. 2-wire 4-20mA. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. GL (German Lloyd) Marine.

    • Nr B Order code TMT181-

      iTEMP TMT181, Head Transmitter PCP

      Temperature transmitter,PC-programmable. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, galvanic isolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. GL (German Llyod) Marine.

    • Nr B Order code TMT182-

      iTEMP TMT182, Head Transmitter HART

      Temperature transmitter, Protocol HART. Application: RTD, TC, Ohm, mV. 2-wire 4-20mA, SIL2, galvanicisolation. Fault reaction: NAMUR NE 43. Mounting: head form B, DIN EN50446. UL listed. GL (German Llyod) Marine.

    • Nr B Order code TMT84-

      iTEMP TMT84, Transmitter PA

      Dual sensor input. Advanced diagnostics:sensor monitoring. PROFIBUS PA Profile 3.02. Galvanic isolation 2kV. Application: RTD, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Nr B Order code TMT85-

      iTEMP TMT85, Transmitter FF

      Dual sensor input. Advanced diagnostics: sensor monitoring. FOUNDATION Fieldbus protocol Galvanic isolation 2 kV. Application: RTC, TC, Ohm, mV. Current consumption: 11 mA. Mounting: head form B, DIN EN50446. Factory setup: CH1: Pt100, 3-wire, oC. CH2: inactive. Differing configuration optional selectable.

    • Order code FXA195-

      Commubox FXA195

      Modem to connect HART field devices to a computer via USB. Commissioning of field devices with software tool. :: To connect to a intrinsically safe signal circuit. :: SIL2, IEC61508.

    • Order code 51001112

      Spare part set for TMT181/187/188/182

      (4 screws, 6 springs, 10 spring rings)