Liquiline Control CDC90 automatically cleans and calibrates your pH and ORP sensors.
Using a touchscreen and a web server, you can conveniently configure, maintain and operate the system and the measuring point.
The system makes it particularly easy to carry out maintenance work, such as changing operating materials.
Liquiline Control CDC90 automatically cleans and calibrates your pH and ORP sensors.
Bruksområde
The Liquiline Control CDC90 plug & play system automates Memosens pH and ORP measuring points in many industries. It cleans, calibrates and adjusts up to two sensors automatically, reducing maintenance effort, improving working safety in harmful areas and helping to ensure the yield and quality of your product. It can easily be integrated into existing plant infrastructures and allows a convenient connection to any process control system.
Liquiline Control CDC90 automates pH and ORP measuring points in all industries. It is suitable for each application where:
The sensors must be cleaned and/or calibrated frequently.
The measuring point is difficult to access.
The measuring point is in a harmful environment.
The process requires reproducible precise pH measurement.
The process requires measurement at frequent intervals.
The performance of the measuring point must be controlled and documented frequently.
Fordeler
Increased occupational safety for your employees: Liquiline Control CDC90 reduces maintenance and servicing measures to a minimum – a decisive advantage, especially in difficult-to-access and hazardous environments.
With customizable cleaning and calibration cycles for up to two sensors, you can achieve high process reliability, product quality and optimum product yield. Blockages and soiling of the sensors are removed in good time.
Intelligent media distribution and dosing guarantees reproducible calibration results and ensures reliable measured values at all times.
Minimize operating costs by optimizing buffer and cleaning agent consumption at both measuring points. This is ensured by the sophisticated hydraulics of the Liquiline Control CDC90.
Seamless integration into your process control system with certified communication standards. Includes analog or digital signals as well as fieldbus: 0/4 ... 20 mA, PROFIBUS DP, Modbus TCP, EtherNet/IP, PROFINET, and web server technology.
Forgjenger
-
Standardprodukter
- Pålitelige, robuste og lette å vedlikeholde
Tekniske egenskaper
Enkelhet
-
Spesialprodukter
- Designet for krevende applikasjoner
Tekniske egenskaper
Enkelhet
Varierende
| FLEX utvalget | Tekniske egenskaper | Enkelhet |
|---|---|---|
Fundamental utvalg Møter dine grunleggende målebehov |
Tekniske egenskaper
|
Enkelhet
|
Lean utvalg Håndter henkelt dine kjerneprosesser |
Tekniske egenskaper
|
Enkelhet
|
Extended utvalg Optimaliser prosessene dine med innovative teknologier |
Tekniske egenskaper
|
Enkelhet
|
Xpert utvalg Mestre de mest utfordrende applikasjonene dine |
Tekniske egenskaper
|
Enkelhet
Varierende |
-
Measuring principle
Potentiometric
-
Application
Increased occupational safety by minimizing maintenance and servicing measures.
Customizable cleaning and calibration cycles for up to two measuring points.
Minimization of operating costs and buffer and cleaning agent consumption through smart media distribution and dosing. -
Installation
Complete automated cleaning and validation system including a selectable retractable holder
-
Characteristic
Fully assembled system with powder-coated or stainless steel pneumatic control unit.
All non-ex applications -
Measuring principle
Automated cleaning and calibration of Memosens pH and ORP sensors installed in retractable assemblies.
-
Design
Complete cleaning and calibration system including dosing pumps and canisters for buffer and cleaning solutions for connection to various retractable assemblies and sensors
-
Dimension
268 x 1170 x 770 mm (l x h x w)
10.55 x 46.06 x 28.74 inch (l x h x w) -
Connection
DCS/PLS connection on Modbus TCP, Ethernet IP, Profinet, ProfibusDP and current in/ output
-
Input
1 to 2x Memosens digital sensor
1x 0/4 to 20mA input
4x digital input -
Output / communication
DCS/PLS connection via Modbus TCP, EtherNet/IP, PROFINET, PROFIBUS DP, digital and analog signals
-
Certificates, declarations and approvals
UKCA, CSA general purpose
-
-
Teknisk informasjon (TI)
TI Liquiline Control CDC90
-
Teknisk informasjon (TI)
Engelsk versjon - 09/2024New version available in EnglishThe smart system for automated measuring points
EN NO 26/09/202423/03/202220/04/202112/12/201931/01/2018Språk:
Engelsk
Versjon:
26/09/2024
Filstørrelse:
2.5 MB
Filnavn:
TI01340CEN_0624-00.pdf
-
-
-
Driftsinstruksjon (BA)
BA Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Engelsk versjon - 03/2026New version available in EnglishData transmission via Modbus TCP
EN NO 25/03/202623/09/202423/03/2022Språk:
Engelsk
Versjon:
25/03/2026
Filstørrelse:
967.6 KB
Filnavn:
BA02238CEN_0326-00.pdf
-
-
-
Driftsinstruksjon (BA)
BA Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Engelsk versjon - 03/2026New version available in EnglishData transmission via PROFIBUS DP
EN NO 25/03/202623/09/202423/03/2022Språk:
Engelsk
Versjon:
25/03/2026
Filstørrelse:
1 MB
Filnavn:
BA02239CEN_0326-00.pdf
-
-
-
Driftsinstruksjon (BA)
BA Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Engelsk versjon - 10/2024New version available in EnglishData transmission via analog communication 0/4 to 20 mA
EN NO 02/10/202423/03/2022Språk:
Engelsk
Versjon:
02/10/2024
Filstørrelse:
772.8 KB
Filnavn:
BA02237CEN_0224-00.pdf
-
-
-
Driftsinstruksjon (BA)
BA Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Engelsk versjon - 03/2026New version available in EnglishData transmission via PROFINET
EN NO 26/03/202623/09/202423/03/2022Språk:
Engelsk
Versjon:
26/03/2026
Filstørrelse:
996 KB
Filnavn:
BA02240CEN_0326-00.pdf
-
-
-
Driftsinstruksjon (BA)
Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Tysk versjon - 03/2022New version available in EnglishDatenübertragung über EtherNet/IP
Språk:
Tysk
Versjon:
23/03/2022
Filstørrelse:
1.1 MB
Filnavn:
BA02241CDE_0122-00.pdf
-
-
-
Driftsinstruksjon (BA)
BA Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Engelsk versjon - 08/2024New version available in EnglishAutomated cleaning and calibration of Memosens sensors
EN NO 01/08/202423/03/202208/02/202106/10/202011/12/2019Språk:
Engelsk
Versjon:
01/08/2024
Filstørrelse:
4.9 MB
Filnavn:
BA01707CEN_0924-00.pdf
-
-
-
Driftsinstruksjon (BA)
BA Liquiline Control CDC90
-
Driftsinstruksjon (BA)
Engelsk versjon - 03/2026New version available in EnglishData transmission via EtherNet/IP
EN NO 26/03/202623/09/202423/03/2022Språk:
Engelsk
Versjon:
26/03/2026
Filstørrelse:
993.4 KB
Filnavn:
BA02241CEN_0326-00.pdf
-
-
-
Kort instruksjon (KA)
KA Liquiline Styreenhet CDC90
-
Kort instruksjon (KA)
Norsk versjon - 08/2024New version available in EnglishAutomatisert rengjøring og kalibrering av Memosens-sensorer
EN NO 01/08/202423/03/202208/02/202122/01/202111/12/2019Språk:
Norsk
Versjon:
01/08/2024
Filstørrelse:
4.6 MB
Filnavn:
KA01306CNO_0724-00.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Einbauanleitung/ Installation Instructions Kit Module/Modules
-
Installasjonsinstruksjoner (EA)
Engelsk versjon - 07/2014New version available in EnglishFür erweiterte Funktionalität
For extended functionalityEN NO 07/07/201425/03/201331/12/2011Språk:
Engelsk
Versjon:
07/07/2014
Filstørrelse:
2.4 MB
Filnavn:
EA00008CA2_0314.pdf
-
Velg en av våre foreslåtte alternativer
-
-- selected coding-- selected label99.999,00<%label%>
-
Leter du etter flere alternativer? Bruk det individuelle konfigurasjonsverktøyet for å fortsette.
-
-- selected coding-- selected label99.999,00<%feature%>
-
<%label%>99.999,00
-
Leter du etter flere alternativer? Bruk det individuelle konfigurasjonsverktøyet for å fortsette.
-
Process Connection
-
<%label%>99.999,00
-
<%label%>99.999,00
-
-
<%feature%><%coding%><%label%>
- CAD-tegninger CAD-tegninger
- CAD-tegninger
-
Pris per enhet
-
<%range%><%price%>
-
- Valgfritt tilbehør
individuell konfigurasjon
Ofte kjøpt sammen
Tilbehør
Beslektede produkter