Spesifikasjonene kort oppsummert
-
Spectral coverage
Starter:
300-3300 cm-1 (785 nm)
Base Model:
150-4350 cm-1 (532 nm)
150-3425 cm-1 (785 nm)
200-2400 cm-1 (1000 nm)
Hybrid: 175-1890 cm-1 (785 nm)
Bruksområde
Adeptly harness the power of Raman spectroscopy with the Raman Rxn2 analyzer. Designed for use in analytical laboratories with model transfer capabilities, the Raman Rxn2 is heavily relied on for routine sample identification, support of R&D projects, early process development, and scale-up settings for in situ analysis. Available as a benchtop or on a mobile wheeled cart, the Raman Rxn2 offers location convenience and portability for process development laboratories.
Chemical: polymerization, extrusion monitoring, polymer blending, catalysis investigation
Pharmaceutical: reaction chemistry, yield crystallization, polymorph, blending, drying, granulations
Biopharmaceutical: bioprocess monitoring and control, PAT/QbD applications, cell culture, fermentation, downstream operations, cGLP/cGMP compatible
Food & Beverage: cultured meat, fermentation, oil or fat quality
Fordeler
Reliable real-time, in situ measurements
Intuitive, embedded control software via touchscreen or remote interface
Convenience of a single base unit supporting up to four probes
-
Sequential operation for fast analysis per channel and programmable channel interrogation
Converts acquired Raman spectra into process knowledge using built-in multivariate predictors
Suitable for outputs into hazardous area/classified environments
Proven model transferability to process development and manufacturing scales
Extended utvalg
-
High- end produkter
- Høyst funksjonelle og praktiske
Tekniske egenskaper
Enkelhet
-
Standardprodukter
- Pålitelige, robuste og lette å vedlikeholde
Tekniske egenskaper
Enkelhet
-
Spesialprodukter
- Designet for krevende applikasjoner
Tekniske egenskaper
Enkelhet
Varierende
FLEX utvalget | Tekniske egenskaper | Enkelhet |
---|---|---|
Fundamental utvalg Møter dine grunleggende målebehov |
Tekniske egenskaper
|
Enkelhet
|
Lean utvalg Håndter henkelt dine kjerneprosesser |
Tekniske egenskaper
|
Enkelhet
|
Extended utvalg Optimaliser prosessene dine med innovative teknologier |
Tekniske egenskaper
|
Enkelhet
|
Xpert utvalg Mestre de mest utfordrende applikasjonene dine |
Tekniske egenskaper
|
Enkelhet
Varierende |
-
-
Teknisk informasjon (TI)
Raman Rxn2 Technical Information
System design and specifications for the Raman Rxn2 analyzer -
powered by Kaiser Raman technologySpråk:
Engelsk
Versjon:
21/11/2023
Filstørrelse:
1.2 MB
Filnavn:
TI01608CEN_0323.pdf
-
-
-
Driftsinstruksjon (BA)
Raman RunTime v6.5 Operating Instructions
Commissioning, operation, and maintenance details
for Raman RunTime v6.5 softwareEN NO 16/11/202316/11/202231/12/2020Språk:
Engelsk
Versjon:
16/11/2023
Filstørrelse:
6.7 MB
Filnavn:
BA02180CEN_0423.pdf
-
-
-
Driftsinstruksjon (BA)
Raman Rxn2 Operating Instructions
Commissioning, operation, and maintenance details for the
Raman Rxn2 analyzer - powered by Kaiser Raman technologySpråk:
Engelsk
Versjon:
21/03/2024
Filstørrelse:
9.1 MB
Filnavn:
BA02151CEN_0524.pdf
-
-
-
Kort instruksjon (KA)
Raman Rxn2 Brief Operating Instructions
Quick start guide for the Raman Rxn2 analyzer -
powered by Kaiser Raman technologySpråk:
Engelsk
Versjon:
21/11/2023
Filstørrelse:
2.5 MB
Filnavn:
KA01544CEN_0323.pdf
-
-
-
Sikkerhetsinstruks for Ex-områder (XA)
Raman Rxn2 Safety Instructions
Hazardous area certifications and installation instructions
for the Raman Rxn2 analyzer - powered by Kaiser Raman technologySpråk:
Engelsk
Versjon:
07/12/2023
Filstørrelse:
1.1 MB
Filnavn:
XA02700CEN_0323.pdf
-
-
-
PU (publikasjon)
Kaiser Raman technology and Sartorius BioPAT Spectro® collaboration Q&A - Scalable, real-time bioprocess monitoring solutions
A Q&A about how our Raman spectroscopy analyzer systems
(including the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
and Rxn-46 probe), powered by Kaiser Raman technology, integrates
with the Sartorius BioPAT Spectro platform (Ambr and biostat STR) for
high throughput and single use (SUB) bioprocessingin the
biopharmaceutical life science industry.Språk:
Engelsk
Versjon:
08/12/2021
Filstørrelse:
943.7 KB
Filnavn:
PU01446CEN_0121.pdf
-
-
-
PU (publikasjon)
Advanced process and product control in fermentations - Raman spectroscopy for composition analysis in a lab or process
An overview of Raman spectroscopy analyzer systems (including the
Raman Rxn2 analyzer, Raman Rxn4 analyzer, Rxn-10 probe, and Rxn-45
probe), powered by Kaiser Raman technology, for fermentation
compositional analysis in a lab or process applicable to biotechnology
in the food & beverage industry.Språk:
Engelsk
Versjon:
03/03/2022
Filstørrelse:
603 KB
Filnavn:
PU01457CEN_0122.pdf
-
-
-
PU (publikasjon)
Raman application guide for the life science industry - Trusted composition analysis for the life sciences
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).Språk:
Engelsk
Versjon:
19/04/2022
Filstørrelse:
1.1 MB
Filnavn:
PU01447CEN_0222.pdf
-
-
-
PU (publikasjon)
Raman flow assembly - Precise composition measurement of high-speed, low-volume samples in downstream bioprocessing
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).Språk:
Engelsk
Versjon:
31/05/2023
Filstørrelse:
837 KB
Filnavn:
PU01517CEN_0123.pdf
-
-
-
PU (publikasjon)
Raman calibration and verification kits - Everything needed to calibrate and verify your Raman analyzer system for lab-to-process scalability
An overview of the Raman calibration and verification kits for
the bio multi optic / single use optic and the Raman flow assembly
(includes the flow bench and flow cell). These kits are to be used in
conjunction with the Rxn-10 probe and Raman Rxn2 / Rxn4 analyzer
for upstream and downstream bioprocessing (powered by Kaiser
Raman technology).Språk:
Engelsk
Versjon:
13/12/2023
Filstørrelse:
2.1 MB
Filnavn:
PU01518CEN_0223.pdf
-