Spesifikasjonene kort oppsummert
-
Accuracy
Rod probe :+/- 2 mm (0.08 in)
Rope probe <= 15 m (49 ft): +/- 2 mm (0.08 in)
Rope probe > 15 m (49 ft): +/- 10 mm (0.39 in)
Coaxial probe: +/- 2 mm (0.08 in) -
Process temperature
-50...+200 °C
(-58...+392 °F) -
Process pressure / max. overpressure limit
Vacuum...40 bar
(Vacuum...580 psi) -
Max. measurement distance
Rod: 10 m (33 ft) Min DK>1.6
Rope: 25 m...30 m (82ft...98 ft) Min DK>1.6;
30m...45 m (98ft...148 ft) Min DK>1,9
Coaxial probe: 6 m (20 ft) Min DK>1.4 -
Main wetted parts
Rod probe:
316L, Alloy C, Ceramic
Rope probe:
316, 316L, Alloy C, Ceramic
Coaxial probe:
316L, Alloy C, Ceramic, PFA
Bruksområde
Levelflex FMP51 for level measurement even under extreme process conditions like
high temperature and high pressure in the process industry. FMP51 offers maximum reliability even in case of moved surface and foam or when numerous tank baffles interfere with the measurement. Levelflex FMP51 is used for continuous level measurement of liquids, pastes and slurries but also for interface measurement. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.
Version with rod, rope or coax probe.
Process connections: Threads or flange
Temperature: -50 to +200°C (-58 to +392°F)
Pressure: -1 to +40bar (-14.5 to +580psi)
Maximum measuring range: Rod 10m (33ft), rope 45m (148ft), coax 6m (20ft)
Accuracy: ±2mm (0.08")
International explosion protection certificates, overfill prevention WHG, SIL, marine approval, 5-point linearity protocol
Fordeler
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Videoer
Extended utvalg
-
High- end produkter
- Høyst funksjonelle og praktiske
Tekniske egenskaper
Enkelhet
-
Standardprodukter
- Pålitelige, robuste og lette å vedlikeholde
Tekniske egenskaper
Enkelhet
-
Spesialprodukter
- Designet for krevende applikasjoner
Tekniske egenskaper
Enkelhet
Varierende
FLEX utvalget | Tekniske egenskaper | Enkelhet |
---|---|---|
Fundamental utvalg Møter dine grunleggende målebehov |
Tekniske egenskaper
|
Enkelhet
|
Lean utvalg Håndter henkelt dine kjerneprosesser |
Tekniske egenskaper
|
Enkelhet
|
Extended utvalg Optimaliser prosessene dine med innovative teknologier |
Tekniske egenskaper
|
Enkelhet
|
Xpert utvalg Mestre de mest utfordrende applikasjonene dine |
Tekniske egenskaper
|
Enkelhet
Varierende |
Forgjenger
-
-
Teknisk informasjon (TI)
Levelflex FMP51, FMP52, FMP54
Engelsk versjon - 02/2023
Guided wave radar
EN NO 22/02/202312/04/202231/07/202004/03/201912/04/2018Språk:
Engelsk
Versjon:
22/02/2023
Filstørrelse:
4.9 MB
Filnavn:
TI01001FEN_2822-00.pdf
-
-
-
Kort instruksjon (KA)
Levelflex FMP51, FMP52, FMP54 HART
Norsk versjon - 04/2022
Ledet radar
EN NO 30/06/202205/04/202212/04/201817/11/201712/02/2015Språk:
Norsk
Versjon:
05/04/2022
Filstørrelse:
1.5 MB
Filnavn:
KA01077FNO_1922-00.pdf
-
-
-
Teknisk informasjon (TI)
Levelflex FMP51 Modbus
Guided wave radar
EN NO 30/06/202228/02/2019Språk:
Engelsk
Versjon:
30/06/2022
Filstørrelse:
3.1 MB
Filnavn:
TI01454FEN_0222-00.pdf
-
-
-
Teknisk informasjon (TI)
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN NO 25/03/202415/09/202328/10/202130/07/202119/06/2020Språk:
Engelsk
Versjon:
25/03/2024
Filstørrelse:
1.1 MB
Filnavn:
TI00426FEN_2524.pdf
-
-
-
Teknisk informasjon (TI)
Levelflex FMP51, FMP52, FMP54
Guided wave radar
EN NO 22/02/202312/04/202231/07/202004/03/201912/04/2018Språk:
Engelsk
Versjon:
22/02/2023
Filstørrelse:
4.9 MB
Filnavn:
TI01001FEN_2822-00.pdf
-
-
-
Driftsinstruksjon (BA)
Levelflex / Levelflex M Zentrierscheibe / Centering disk (PFA) Mounting Instructions
Accessory
EN NO 29/09/201727/02/201425/04/201208/02/201124/09/2010Språk:
Engelsk
Versjon:
29/09/2017
Filstørrelse:
82.6 KB
Filnavn:
BA00378FA2_1717.pdf
-
-
-
Driftsinstruksjon (BA)
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Guided wave radar
EN NO 21/02/202330/06/202212/04/201816/11/201715/12/2016Språk:
Engelsk
Versjon:
21/02/2023
Filstørrelse:
4.7 MB
Filnavn:
BA01006FEN_2022-00.pdf
-
-
-
Driftsinstruksjon (BA)
Accessory
Centering star PEEK
EN NO 27/02/201424/09/201003/12/200802/04/2008Språk:
Engelsk
Versjon:
27/02/2014
Filstørrelse:
99.3 KB
Filnavn:
BA00377FA2_1414.pdf
-
-
-
Driftsinstruksjon (BA)
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Guided wave radar
EN NO 21/02/202330/06/202212/04/201816/11/201715/12/2016Språk:
Engelsk
Versjon:
21/02/2023
Filstørrelse:
5.9 MB
Filnavn:
BA01052FEN_0822-00.pdf
-
-
-
Driftsinstruksjon (BA)
Levelflex FMP51, FMP52, FMP54 HART
Guided wave radar
EN NO 13/12/202230/06/202231/07/202012/04/201816/11/2017Språk:
Engelsk
Versjon:
13/12/2022
Filstørrelse:
5.3 MB
Filnavn:
BA01001FEN_2422-00.pdf
-
-
-
Driftsinstruksjon (BA)
Levelflex FMP51 Modbus
Guided wave radar
EN NO 12/04/202204/03/2019Språk:
Engelsk
Versjon:
12/04/2022
Filstørrelse:
4.5 MB
Filnavn:
BA01957FEN_0222-00.pdf
-
-
-
Enhetsparameter (GP)
Levelflex FMP5x Modbus Description of Device Parameters
Guided wave radar
EN NO 04/03/2019Språk:
Engelsk
Versjon:
04/03/2019
Filstørrelse:
3 MB
Filnavn:
GP01140FEN_0119.pdf
-
-
-
Enhetsparameter (GP)
Levelflex FMP5x HART Description of Device Parameters
Guided wave radar
EN NO 28/04/201630/10/201426/02/201429/07/201101/10/2010Språk:
Engelsk
Versjon:
28/04/2016
Filstørrelse:
3.3 MB
Filnavn:
GP01000FEN_1616.pdf
-
-
-
Enhetsparameter (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 PROFIBUS PA Description of Device Parameters
Guided wave radar
EN NO 30/10/201404/08/2011Språk:
Engelsk
Versjon:
30/10/2014
Filstørrelse:
4.7 MB
Filnavn:
GP01001FEN_1314.pdf
-
-
-
Enhetsparameter (GP)
Levelflex FMP50, FMP51, FMP52, FMP53, FMP54, FMP55, FMP56, FMP57 FOUNDATION Fieldbus Description of Device Parameters
Guided wave radar
EN NO 09/06/201527/04/2012Språk:
Engelsk
Versjon:
09/06/2015
Filstørrelse:
3.5 MB
Filnavn:
GP01015FEN_0215.pdf
-
-
-
Kort instruksjon (KA)
Levelflex FMP51, FMP52, FMP54 HART
Ledet radar
EN NO 30/06/202205/04/202212/04/201817/11/201712/02/2015Språk:
Norsk
Versjon:
05/04/2022
Filstørrelse:
1.5 MB
Filnavn:
KA01077FNO_1922-00.pdf
-
-
-
Kort instruksjon (KA)
Levelflex FMP51, FMP52, FMP54 FOUNDATION Fieldbus
Ledet radar
EN NO 30/06/202205/04/202212/04/201830/11/201717/11/2017Språk:
Norsk
Versjon:
05/04/2022
Filstørrelse:
1.3 MB
Filnavn:
KA01107FNO_0722-00.pdf
-
-
-
Kort instruksjon (KA)
Levelflex FMP51, FMP52, FMP54 PROFIBUS PA
Ledet radar
EN NO 30/06/202205/04/202212/04/201817/11/201712/02/2015Språk:
Norsk
Versjon:
05/04/2022
Filstørrelse:
1.3 MB
Filnavn:
KA01079FNO_1722-00.pdf
-
-
-
Kort instruksjon (KA)
Levelflex FMP51 Modbus
Ledet radar
EN NO 30/06/202205/04/202204/03/2019Språk:
Norsk
Versjon:
05/04/2022
Filstørrelse:
1.4 MB
Filnavn:
KA01421FNO_0222-00.pdf
-
-
-
Kort instruksjon (KA)
Screw set for Micropilot II/M, Levelflex M, Prosonic M
Screw set for Micropilot II/M, Levelflex M, Prosonic M
EN NO 15/04/2021Språk:
Engelsk
Versjon:
15/04/2021
Filstørrelse:
532.2 KB
Filnavn:
KA00512F00_A2.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Display module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x
EN NO 08/06/2018Språk:
Engelsk
Versjon:
08/06/2018
Filstørrelse:
345.1 KB
Filnavn:
EA01247FA2_0118.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Rope centering disk, Rope centering weight
Levelflex FMP51, FMP54
EN NO 01/10/2021Språk:
Engelsk
Versjon:
01/10/2021
Filstørrelse:
566.2 KB
Filnavn:
EA01382FEN_0121.pdf
-
-
-
Installasjonsinstruksjoner (EA)
M12 connector, IP66/68 NEMA4X/6P, ProToF Installation Instructions
Levelflex FMP5x
Micropilot FMR5x, FMR6xEN NO 01/10/2019Språk:
Engelsk
Versjon:
01/10/2019
Filstørrelse:
349 KB
Filnavn:
EA01289FEN_0119.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Set housing security clamp Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200,EN NO 31/08/201707/10/201305/01/2012Språk:
Engelsk
Versjon:
31/08/2017
Filstørrelse:
279.5 KB
Filnavn:
EA00038FA2_1717.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Main electronics module Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x
EN NO 31/08/201714/04/201408/01/2013Språk:
Engelsk
Versjon:
31/08/2017
Filstørrelse:
281.5 KB
Filnavn:
EA00041FA2_1617.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Replacing the display module Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50EN NO 01/09/201701/02/201724/11/201528/11/201306/04/2012Språk:
Engelsk
Versjon:
01/09/2017
Filstørrelse:
562.2 KB
Filnavn:
EA00102DA2_1817.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Cover Installation Instructions
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x Promag 200, Promass
200, Prosonic Flow 200, Prowirl 200, Remote display FHX50EN NO 28/06/201828/02/201718/11/201524/02/201502/10/2013Språk:
Engelsk
Versjon:
28/06/2018
Filstørrelse:
517.9 KB
Filnavn:
EA00035FA2_2018.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Replacing the main electronics module Installation Instructions
Promass 200 / TB2, Prosonic Flow 200, Promag 200
EN NO 01/10/201818/08/201429/06/2012Språk:
Engelsk
Versjon:
01/10/2018
Filstørrelse:
485.9 KB
Filnavn:
EA00103DA2_1718.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Set HF cable for compact and remte versions Installation Instruction
Levelflex
EN NO 17/07/202010/02/201519/07/2011Språk:
Engelsk
Versjon:
17/07/2020
Filstørrelse:
1.8 MB
Filnavn:
EA00059FA2_0320.pdf
-
-
-
Installasjonsinstruksjoner (EA)
EA Probe with process connection
Levelflex FMP5x
EN NO 17/01/202412/04/2012Språk:
Engelsk
Versjon:
17/01/2024
Filstørrelse:
848.1 KB
Filnavn:
EA00045FEN_0424-00.pdf
-
-
-
Installasjonsinstruksjoner (EA)
probe rod, rope without process connection for FMP50, FMP51 Installation instruction
Levelflex FMP50, FMP51
EN NO 12/04/2012Språk:
Engelsk
Versjon:
12/04/2012
Filstørrelse:
425.2 KB
Filnavn:
EA00043FA2_0211.pdf
-
-
-
Installasjonsinstruksjoner (EA)
Probe weight for FMP5x Installation instruction
Levelflex
EN NO 12/04/2012Språk:
Engelsk
Versjon:
12/04/2012
Filstørrelse:
273.4 KB
Filnavn:
EA00042FA2_0111.pdf
-