The Flowfit CCA250 flow assembly is specially designed to accommodate all sensors needed for accurate disinfection control - the chlorine sensor and the pH/ORP sensors for compensation and measurement. It increases the availability of sensors and offers an integrated flow alarm and adjustment to make sure that your bypass measurement is always operational. With CCA250, you have complete control of your disinfection processes and the water is always free of germs.
CCA250 is a flow assembly for the measurement of free chlorine, total chlorine and chlorine dioxide in:
Drinking water - Trace and standard measurement in process water and distribution networks - Monitoring, control and optimization of disinfection processes
Utilities of all industries - Trace and standard measurement in all disinfection applications - Process applications, e.g. bottle rinsing machines
Pool water
Fordeler
All sensors needed for disinfection measurement comfortably in one place
Suitable for all disinfection processes - free chlorine, chlorine dioxide, total chlorine and others
Cap screwed from below allows calibration of the pH and ORP sensors without sensor removal
Flow alarm can be activated
Needle valve to adjust the flow and flow meter for optical control
AVR Waste i Botlek, Rotterdam behandler opptil 1,7 millioner tonn restavfall hvert år. Se hvordan de optimaliserte pH-målinger takket være Endress+Hauser
Bruk av sjøvann til å spyle ned i toaletter kan spare mye drikkevann. For å sikre en konstant vanntilførsel må sensorene som brukes, fungere pålitelig for å oppfylle målene for vannkvalitet (WQO).
Undersøkelse av avløpsvann ved bruk av Liquistation CSF48 og Liquiport CSP48 mobile kan gi verdifull informasjon om forekomsten av covid 19-infeksjoner i et spesifikt område
Sikkerhet og driftskomfort for analytiske målepunkter starter med riktig sammensetting. Vår fleksible produksjonslinje sikrer at du får riktig tilpasning til dine behov.
- Flow through holder with 3 different emplacements : 1x chlorine/chlordioxide/total chlorine sensor and 2x pH/ORP sensor.
Design
- Flow through holder made of plexiglas with flow control and proximity switch as alarm relais to the transmitter. - Three different emplacements - Calibration directly in the holder because of the screw off calibration cap. - Optional cleaning device for the chlorine/chlordioxide/total chlorine sensor.
Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent
Total chlorine consists of free chlorine (HOCl, OCl-) and bound chlorine (chloramines) All components are reduced at the working electrode Almost pH independent