©Endress+Hauser
Spesifikasjonene kort oppsummert
Output / communication
0/4-20 mA, Hart, Profibus
Bruksområde
Liquisys CPM253 is a standard pH/ORP transmitter for all analog and digital Memosens sensors. It improves your operational safety thanks to continuous plausibility, process and sensor checks. Select from numerous hardware and software modules, such as relays or fieldbus communication, to adapt it exactly to your measuring task. This modularity also allows you to upgrade the transmitter at any time. A simple menu and two-point calibration make configuration and operation fast and easy.
The Liquisys CPM253 transmitter works with all pH/ORP glass and ISFET sensors in non-hazardous areas, for example in these industries and their utilities:
Chemicals
Food & Beverages
Power & Energy
Water & Wastewater
Primaries & Metal
Liquisys CPM253 features the following protocols and interfaces:
0/4...20 mA
HART
PROFIBUS DP
PROFIBUS PA
Fordeler
More operational safety: Continuous process check system, customized alarm configuration, proven Memosens interface for reliable sensor connection.
Reliable self-monitoring: Sensor check system for pH glass and reference, calibration plausibility check.
Easy to operate and service: Intuitive user interface, hot plug & play with pre-calibrated Memosens sensors, direct access for manual contact control.
Reduced maintenance: Automatic cleaning function (with Chemoclean) triggered by alarm or limit switch.
Fit for every application: Numerous extensions, such as P(ID) controller, timer, etc., allow for flexible adaption to all processes.
Forgjenger
CPM141S
CPM240S
CPM140
CPM130
CPM141
Suksesshistorier
Automatisert system for pH-målinger på AVR
AVR Waste i Botlek, Rotterdam behandler opptil 1,7 millioner tonn restavfall hvert år. Se hvordan de optimaliserte pH-målinger takket være Endress+Hauser
Les hele artikkelen
Rent høykvalitetsøl og rent avløpsvann
Oppdag hvordan Heineken oppfyller alle bestemmelser for å beskytte det brasilianske miljøet med den digitale nitrat- eller SAC-sensoren Viomax CAS51D fra Endress+Hauser.
Les hele artikkelen
Enkle produkter
Enkelt å velge, intallere og bruke
Tekniske egenskaper
Enkelhet
Standardprodukter
Pålitelige, robuste og lette å vedlikeholde
Tekniske egenskaper
Enkelhet
High- end produkter
Høyst funksjonelle og praktiske
Tekniske egenskaper
Enkelhet
Spesialprodukter
Designet for krevende applikasjoner
Tekniske egenskaper
Enkelhet
FLEX utvalget
Tekniske egenskaper
Enkelhet
Fundamental utvalg
Møter dine grunleggende målebehov
Tekniske egenskaper
Enkelhet
Lean utvalg
Håndter henkelt dine kjerneprosesser
Tekniske egenskaper
Enkelhet
Extended utvalg
Optimaliser prosessene dine med innovative teknologier
Tekniske egenskaper
Enkelhet
Xpert utvalg
Mestre de mest utfordrende applikasjonene dine
Tekniske egenskaper
Enkelhet
Dette kan også være av interesse for deg
Application
Water, waste water, process
Design
pH/ORP field housing made of PC/ABS
Dimension
247x170x115mm (9.63x6.63x4.48inch)
Temperature sensor
Display and current output
Output / communication
0/4-20 mA, Hart, Profibus
Additional certifications
Application
Water, waste water, process
Design
pH/ORP-field housing made of PC/ABS
Temperature sensor
Display and current output
Output / communication
0/4-20mA, Hart, Profibus.
Additional certifications
Mest nedlastet
Operating Instructions Liquisys M CXM223/253 HART
Engelsk versjon - 10/2005
Field Communication with Liquisys M CXM223/253
EN
NO
DE FR
01/10/2005
01/07/2002
Språk:
Engelsk
Versjon:
01/10/2005
Filstørrelse:
541.4 KB
Filnavn:
BA208CEN.pdf
Liquisys M CPM223/253
Operating Instructions
Engelsk versjon - 09/2015
Transmitter
EN
NO
CS DA DE ES FI FR HU IT JA PL PT RU ZH
01/09/2015
24/10/2013
20/06/2011
01/12/2005
01/03/2005
Språk:
Engelsk
Versjon:
01/09/2015
Filstørrelse:
2.7 MB
Filnavn:
BA00194CEN_1515.pdf
29 dokumenter
Liquisys M CPM223/253
Technical Information
pH/ORP measurement
EN
NO
Tysk French Italiensk Japansk Polsk Russisk Tyrkisk Kinesisk
30/09/2014
24/10/2013
20/06/2011
01/09/2007
01/04/2004
Språk:
Engelsk
Versjon:
30/09/2014
Filstørrelse:
999.7 KB
Filnavn:
TI00194CEN_1514.pdf
Technical Information CCM 223/
Measurement of chlorine / chlorine dioxide/ total chlorine Transmitter for chlorine sensors
EN
NO
Tysk French Italiensk Japansk Kinesisk
24/10/2013
20/06/2011
01/07/2006
01/09/2000
Språk:
Engelsk
Versjon:
24/10/2013
Filstørrelse:
642.3 KB
Filnavn:
TI00214CEN_1413.pdf
Operating Instructions Liquisys M CXM223/253 HART
Field Communication with Liquisys M CXM223/253
EN
NO
Tysk French
01/10/2005
01/07/2002
Språk:
Engelsk
Versjon:
01/10/2005
Filstørrelse:
541.4 KB
Filnavn:
BA208CEN.pdf
Operating Instructions Liquisys M CXM223/253 PROFIBUS
Field Communikation for Liquisys M CXM223/253
EN
NO
Tysk French Italiensk Polsk
01/12/2011
01/08/2009
01/09/2007
01/07/2006
01/10/2005
Språk:
Engelsk
Versjon:
01/12/2011
Filstørrelse:
1.7 MB
Filnavn:
BA209CEN_1311.pdf
Liquisys M CPM223/253
Operating Instructions
Transmitter
EN
NO
Tsjekkisk Dansk Tysk Spansk Finsk French Ungarsk Italiensk Japansk Polsk Portugisisk Russisk Kinesisk
01/09/2015
24/10/2013
20/06/2011
01/12/2005
01/03/2005
Språk:
Engelsk
Versjon:
01/09/2015
Filstørrelse:
2.7 MB
Filnavn:
BA00194CEN_1515.pdf
Ex-safety instructions CXM2X3
Safety instructions for electrical apparatus for explosion-hazardous areas as per EC Directive 94/9/EC (ATEX)
EN
NO
Tysk French
07/06/2005
27/09/2004
29/02/2004
Språk:
Engelsk
Versjon:
07/06/2005
Filstørrelse:
2.5 MB
Filnavn:
XA194CA3.pdf
Additional information for CSA Liquisys
Additional information for CSA Liquisys
Språk:
Engelsk
Versjon:
24/09/2013
Filstørrelse:
84.3 KB
Filnavn:
CXM2X3_Beiblatt for CSA.pdf
Installation of M 12 plug
Special Documentation Installation of M 12 plug CPM253 / COM253 / CLM253 / CUM253
Språk:
Engelsk
Versjon:
01/10/1999
Filstørrelse:
85.5 KB
Filnavn:
SD052CA2.pdf
Instructions for service kits Liquisis M
Special documents Instructions for service kits Liquisis M / CPM253 / CLM253 / COM253 / CUM253
Språk:
Engelsk
Versjon:
01/05/2000
Filstørrelse:
198.2 KB
Filnavn:
SD084CA2.pdf
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates (following the NAMUR recommendation 53) New software version: 1.12.00
EN
NO
Tysk
30/07/2015
13/01/2015
15/04/2014
07/01/2014
18/03/2013
Språk:
Engelsk
Versjon:
30/07/2015
Filstørrelse:
438.9 KB
Filnavn:
MI00095S_04_en_10.15.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Tegningsnummer
Ordrekode
410,420,46
51501068
Kit CxM253: Front foil + 6 key lifters
Tegningsnummer
Ordrekode
335
71071446
KIT CXM253 Internal housing parts
Tegningsnummer
Ordrekode
330,340,45
51501073
Transmitter connector set M12 Fieldbus
KIT CXM253 bottom of housing
Tegningsnummer
Ordrekode
400
51501072
KIT CXM/153/253: 2 pair of hinges
Tegningsnummer
Ordrekode
430
51501069
KIT CXM253 Ground terminal strip
Tegningsnummer
Ordrekode
490
51501087
KIT CXM253 terminal strip power supply
Tegningsnummer
Ordrekode
470
51501079
Tegningsnummer
Ordrekode
310
51501074
KIT CPM2X3 Central module I1
Tegningsnummer
Ordrekode
40
51501081
KIT CPM2x3 central module I1 HART
Tegningsnummer
Ordrekode
40
51501083
KIT CPM2x3 Central modul I2
Tegningsnummer
Ordrekode
40
51501082
KIT CPM2x3 central module I2 HART
Tegningsnummer
Ordrekode
40
51501084
KIT CPM2X3 central module Profibus PA
Tegningsnummer
Ordrekode
40
51501085
Kit CPM2X3 central module Profibus DP
Tegningsnummer
Ordrekode
40
51502503
Kit CPM2x3: Central mod. PB DP; H/W 2.1x
Tegningsnummer
Ordrekode
40
71134724
Kit CxM2x3: Relay mod. for PBDP; H/W2.1x
Tegningsnummer
Ordrekode
290
71134732
KIT MKP2 Transmitter module pH/ORP/IsFET
Tegningsnummer
Ordrekode
230
51507096
KIT MKP3 transmitter module pH/ORP
Tegningsnummer
Ordrekode
230
51518244
KIT MKD1 Memosens-Transmittermodule cpl.
Tegningsnummer
Ordrekode
230
51514966
KIT CXM2X3 power supply 100..230 V AC
Tegningsnummer
Ordrekode
10
51500317
KIT CxM2x3 power supply 24 AC/DC
Tegningsnummer
Ordrekode
20
51500318
Kit CXM2X3 Relaismod. 2rel
KIT CXM2X3 relay mod. 2rel / CSA
Tegningsnummer
Ordrekode
290
51511446
Kit CXM2X3 Relaismodule 4rel
Tegningsnummer
Ordrekode
300
51500321
KIT CXM2X3 relay mod. 4rel / CSA
Tegningsnummer
Ordrekode
300
51511447
Kit CXM2X3 Relais Mod. 2rel.+I/CSA
Tegningsnummer
Ordrekode
290
51504304
Kit CXM2X3 Relais Mod. 4Rel+I/CSA
Tegningsnummer
Ordrekode
300
51504305
KIT CPM253 pH/mV terminal+screen plate
Tegningsnummer
Ordrekode
999
51501071
Post mounting kit for LIQUISYS
Upgrade "Plus-Package" for LIQUISYS-M
Upgrade cleaning for LIQUISYS-M
Vi verdsetter personvernet ditt
Vi bruker informasjonskapsler til å forbedre surfeopplevelsen din, samle inn statistikk for å optimalisere nettstedsfunksjonalitet og vise skreddersydde annonser eller skreddersydd innhold.
Ved å velge «Godta alle» samtykker du i bruken vår av informasjonskapsler.
Du finner mer informasjon i retningslinjene våre for informasjonskapsler .
Tilpasse
Godta bare det essensielle
Godta alle