Du må skrive inn minst 2 tegn for å starte søket.

Hydrostatic Level measurement
Waterpilot FMX11

Waterpilot FMX11 - Hydrostatic level measurement ©Endress+Hauser
Reliable level probe for clean water applications ©Endress+Hauser
Simple and reliable transmitter for various drinking water applications ©Endress+Hauser

Pressure measuring principle

Simple and reliable level probe for freshwater applications

The Waterpilot FMX11 transmitter is typically used in environmental applications for hydrostatic level measurement. It is certified for drinking water applications and can be used in wells, storage tanks, water towers, dams, gauging stations, lakes and rivers.

  • Enkle produkter

  • Enkelt å velge, intallere og bruke

Tekniske egenskaper

Enkelhet

  • Standardprodukter

  • Pålitelige, robuste og lette å vedlikeholde

Tekniske egenskaper

Enkelhet

  • High- end produkter

  • Høyst funksjonelle og praktiske

Tekniske egenskaper

Enkelhet

  • Spesialprodukter

  • Designet for krevende applikasjoner

Tekniske egenskaper

Enkelhet

Varierende

FLEX utvalget Tekniske egenskaper Enkelhet
  • F
  • L
  • E
  • X

Fundamental utvalg

Møter dine grunleggende målebehov

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Lean utvalg

Håndter henkelt dine kjerneprosesser

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Extended utvalg

Optimaliser prosessene dine med innovative teknologier

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Xpert utvalg

Mestre de mest utfordrende applikasjonene dine

Tekniske egenskaper
Enkelhet

Varierende

  • Spesifikasjonene kort oppsummert

    • Accuracy

      pn ≥ 400mbar: 0.35 %
      pn < 400mbar: 0.50 %

    • Process temperature

      -10°C...+70°C
      (+14°F...+158°F)

    • Pressure measuring range

      200 mbar...2 bar
      (3 psi...29 psi)

    • Process pressure absolute / max. overpressure limit

      10 bar (145 psi)

    • Main wetted parts

      316L

    • Max. measurement distance

      200 m H2O
      (656 ft H2O)

    • Material process membrane

      Metal

    • Measuring cell

      200 mbar...2 bar
      (3 psi...29 psi)

please wait Loading alternative products

Hurtigvalg

Velg ett av våre foreslåtte alternative
Salgspris
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

eller

individuell konfigurasjon

Fortsett for å velge blant alle mulige alternativer
  • Fordeler

    • Simple and reliable transmitter for various drinking water applications

    • Easy installation, commissioning and operation

    • Orderable with flexible measuring ranges and cable lengths tailored to fit your application

    • Robust construction for durable long-term...

  • Bruksområde

    • Temperature: –10 to +70°C (14 to 158°F)

    • Measuring range: 0 to 2bar / 20m H20 (0 to 30psi / 67ft H2O)

    • Cable length: 6 to 30m

    • Accuracy: up to ±0.35%

    • Drinking water approvals: ACS, KTW, NSF61, DVGW

    • Certifications: cULus

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Hydrostatic pressure

  • Characteristic

    Compact probe with metallic cell for hydrostatic level measurement

    in fresh water, ground water and potable water storage.

  • Supply voltage

    8...28 VDC

  • Reference Accuracy

    pn ≥ 400mbar: 0.35 %

    pn < 400mbar: 0.50 %

  • Long term stability

    0.1 % of URL/year

  • Process temperature

    -10°C...+70°C

    (+14°F...+158°F)

  • Ambient temperature

    -10°C...+70°C

    (+14°F...+158°F)

  • Measuring cell

    200 mbar...2 bar
    (3 psi...29 psi)

  • Process connection

    Suspension clamp

    Cable mounting screws

  • Material process membrane

    Metal

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS

  • Measuring principle

    Hydrostatic

  • Characteristic / Application

    Compact probe with metallic cell for hydrostatic level measurement

    in fresh water, ground water and potable water storage.

  • Supply / Communication

    8...28 VDC

  • Accuracy

    pn ≥ 400mbar: 0.35 %

    pn < 400mbar: 0.50 %

  • Long term stability

    0.1% of URL/year

  • Ambient temperature

    -10°C...+70°C

    (+14°F...+158°F)

  • Process temperature

    -10°C...+70°C

    (+14°F...+158°F)

  • Process pressure absolute / max. overpressure limit

    10 bar (145 psi)

  • Pressure measuring range

    200 mbar...2 bar
    (3 psi...29 psi)

  • Main wetted parts

    316L

  • Process connection

    Suspension clamp

    Cable mounting screws

  • Max. measurement distance

    200 m H2O

    (656 ft H2O)

  • Communication

    4...20 mA

  • Drinking water approvals

    NSF, KTW, ACS

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification