Du må skrive inn minst 2 tegn for å starte søket.

Liquiphant FTL62 - the coated sensor for aggressive media

Liquiphant FTL62 with bluetooth module ©Endress+Hauser
Liquiphant FTL62 with LED module ©Endress+Hauser

The new Liquiphant FTL62

Liquiphant FTL62 with LED module ©Endress+Hauser

Preventive maintenance is possible with corrosion detection via Heartbeat Technology

Liquiphant with permanent function check is the safe choice for point level detection in liquids

A level switch for aggressive and pumpable liquids

Liquiphant FTL62 has a strong focus on specific applications with aggressive liquids and simplicity with easy proof testing, reliability and safety (SIL) with compliance to IEC 61508, API 2350 and WHG. The vibronic device is determined for a safe and active measuring technology in aggressive liquids and want a reliable and proven point level detection for tank overfill prevention and pump dry run protection. The FTL62 is easy to use, has a digital connection and gives a real-time data at hand.

  • Enkle produkter

  • Enkelt å velge, intallere og bruke

Tekniske egenskaper

Enkelhet

  • Standardprodukter

  • Pålitelige, robuste og lette å vedlikeholde

Tekniske egenskaper

Enkelhet

  • High- end produkter

  • Høyst funksjonelle og praktiske

Tekniske egenskaper

Enkelhet

  • Spesialprodukter

  • Designet for krevende applikasjoner

Tekniske egenskaper

Enkelhet

Varierende

FLEX utvalget Tekniske egenskaper Enkelhet
  • F
  • L
  • E
  • X

Fundamental utvalg

Møter dine grunleggende målebehov

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Lean utvalg

Håndter henkelt dine kjerneprosesser

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Extended utvalg

Optimaliser prosessene dine med innovative teknologier

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Xpert utvalg

Mestre de mest utfordrende applikasjonene dine

Tekniske egenskaper
Enkelhet

Varierende

  • Spesifikasjonene kort oppsummert

    • Process temperature

      -50 °C...+150 °C
      (-58 °F...+302 °F)

    • Process pressure absolute / max. overpressure limit

      Vacuum...40 bar
      Vacuum...580 psi

    • Min. density of medium

      0.5 g/cm³
      (0.4 g/cm³ optional)

please wait Loading alternative products

Hurtigvalg

Velg ett av våre foreslåtte alternative
Salgspris
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

eller

individuell konfigurasjon

Fortsett for å velge blant alle mulige alternativer
  • Fordeler

    • Universal measuring principle for limit detection – proven vibronic technology

    • Developed according IEC 61508 for highest safety – SIL2/3 applications (3rd party approved)

    • Periodic proof testing is quickly and simple organized with guided wizards via the...

  • Bruksområde

    Point level switch with extension tube for pumpable liquids

    • Coated sensor for aggressive media: ECTFE (Halar), PFA (EdlonTM, Ruby Red, conductive), Enamel

    • Process temperature: -60 °C to +150°C

    • Process pressure: -1 to +40bar

    • Ambient temperature: -60...

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Vibration Liquids

  • Characteristic / Application

    Compact vibronic device with highly corrosion-resistant coating for aggressive media,
    Optional extension tube up to 3 m (9.8ft),

    Modular housing concept

  • Specialities

    Heartbeat Technology,

    Bluetooth® Operation and maintenance SmartBlue App,

    LED Module,

    RFID TAG for easy identification,

    Second line of defense

    Temperature spacer for high process temperature,

    Plug and play functionalities

  • Supply / Communication

    19...253V AC / 2-wire,

    10...55V / DC-PNP 3-wire,

    9...20V DC with relay DPDT,

    19...253V AC or 19...55V DC with relay DPDT,

    2-wire NAMUR,

    2-wire PFM

  • Ambient temperature

    -60 °C...+70 °C

    (-51 °F...+158 °F)

  • Process temperature

    -50 °C...+150 °C

    (-58 °F...+302 °F)

  • Process pressure absolute / max. overpressure limit

    Vacuum...40 bar

    Vacuum...580 psi

  • Min. density of medium

    0.5 g/cm³

    (0.4 g/cm³ optional)

  • Main wetted parts

    ECTFE,

    PFA (Edlon, RubyRed or conductive)

    316L

    Enamel

  • Process connection

    Flanges:

    DN25...DN100

    ASME 1"...4"

    JIS 50A

  • Sensor length

    Up to 3 m (9.8ft)

  • Communication

    2-wire direct load

    DC-PNP 3-wire

    Relays

    NAMUR

    PFM

    Bluetooth® wireless technology

  • Certificates / Approvals

    ATEX, IEC Ex

  • Safety approvals

    Overfill protection WHG

    SIL2/ SIL 3 according to IEC 61508

  • Design approvals

    EN 10204-3.1

    ASME B31.3 Process Piping

    CRN

  • Marine approval

    ABS/ LR/ BV/ DNV GL

  • Options

    Ambient temperature down to -60 °C (-76 °F),

    Heavy duty stainless steel housing

  • Components

    FTL325P Interface PFM

    FTL325N Interface NAMUR

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification
  • 15
    • Nr 15 Order code 71435135

      Cable gland M20, plastic

      Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.

    • Nr 15 Order code 71435136

      Cable gland M20, brass nickel plated

      Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.

    • Nr 15 Order code 71435137

      Cable gland M20, 316L

      Usage: FMG50, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.

    • Nr 15 Order code 71435138

      M12 plug,CuZn-nickel plated,housing side

      Usage: M12 screw-in thread, brass nickel plated, FMG50, FTL51B, FTL62/FTL64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B,PMP51B, PMP71B.

  • 20
    • Nr 20 Order code 71435116

      Cover, Alu, closed

      Sealing ring, HNBR. Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B,PMP51B, PMP71B.

    • Nr 20 Order code 71435118

      Cover, Alu, closed, Ex d

      Sealing ring, HNBR. Usage: FMG50, FTL41, FTL51B, FTL62/64, PMC51B, PMC71B, PMD55B, PMD75B/PMD78B, PMP51B, PMP71B.

    • Nr 20 Order code 71435122

      Cover, 316L, closed, Ex d

      Sealing ring, HNBR. Usage: FMG50, FTL51B, FTL62/64, PMD75B/PMD78B, PMC71B, PMP71B.

    • Nr 20 Order code 71435126

      Cover, plastic, closed

      Sealing ring, EPDM. Usage: FTL41, FTL51B, FTL62/64.

    • Nr 20 Order code 71435127

      Cover, plastic, BT/LED module

      Sealing ring, EPDM. For Bluetooth/LED module. Usage: FTL51B, FTL62/64.

    • Nr 20 Order code 71435129

      Cover, Alu, sight window, BT/LED module

      Sealing ring, HNBR. Material sight window: plastic. For Bluetooth/LED module. Usage: FTL51B, FTL62/64.

    • Nr 20 Order code 71435130

      Cover, Alu, sight window, Ex d, BT/LED

      Sealing ring, HNBR. Material sight window: glass. For Bluetooth/LED module. Usage: FTL51B, FTL62/64.

    • Nr 20 Order code 71435123

      Cover, 316L, sight window, Ex d

      Sealing ring, HNBR. Usage: FMG50, FTL51B, FTL62/FTL64, PMD75B/PMD78B, PMC71B, PMP71B.

  • 21
  • 30
    • Nr 30 Order code 71432518

      Electronics FEL61, 19-253VAC

      2-wire incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432519

      Electronics FEL62, PNP10-55VDC

      3-wire incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432547

      Electronics FEL62, PNP10-55VDC, -60oC

      3-wire incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432549

      Electronics FEL64 DC, relay DPDT

      9-20VDC, contact 253V/6A incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432553

      Electronics FEL64 DC, relay DPDT, -60oC

      9-20VDC, contact 253V/6A incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432570

      Electronics FEL64, relay DPDT

      19-253VAC/19-55VDC, contact 253V/6A incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432572

      Electronics FEL64, relay DPDT, -60oC

      19-253VAC/19-55VDC, contact 253V/6A incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432573

      Electronics FEL67 PFM

      2-wire PFM incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432574

      Electronics FEL67 PFM, -50oC

      2-wire PFM incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432575

      Electronics FEL68 NAMUR

      2-wire, NAMUR H-L signal incl. test button. Usage: FTL51B.

    • Nr 30 Order code 71432576

      Electronics FEL68 NAMUR, -50oC

      2-wire, NAMUR H-L signal incl. test button. Usage: FTL51B, FTL62/64.

    • Nr 30 Order code 71432577

      Electronics FEL60D,density/concentration

      Usage: FTL51B, FTL62/64.

  • 40
    • Order code XPF0040-

      Housing 2-wire platform Liquiphant

      Usage: FTL41, FTL51B, FTL62, FTL64.

    • Order code 71437508

      Test magnet, FTL51B

      Usage: FTL51B, FTL62/FTL64.

    • Order code 52010285

      M12-female plug connec., 90deg, 5m cable

      M12 plug socket, cable side. 5m cable PVC, Cu Sn/Ni lock. Usage: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33, FTL51B, FTL62/FTL64, FTW23, FTW33, PMC11, PMC21, PMC51, PMP11, PMP21/PMP23, PMP51/PMP55, PTC31B, PTP31B/PTP33B, QMW43.

    • Order code 52024216

      Cable 4x0,34, box M12, 316L, 90o, L=5m

      M12x1 plug. 5m cable PVC, 316L lock. Especially for hygiene applications. Usage: FTL33, FTL50, FTL51B, FTL62/FTL64, FTL80/FTL81/FTL85, FTW23, FTW33, QMW43.

    • Order code 71438291

      Weather protection cover, plastic, XW111

      Usage: FTL41, FTL51B, FTL62/FTL64, PMC51B, PMD55B, PMP51B.

    • Order code 71438303

      Weather protection cover, 316L, XW112

      Usage: FMG50, FTL51B, FTL62/FTL64, PMC71B, PMD75B/PMD78B, PMP71B.