Du må skrive inn minst 2 tegn for å starte søket.

Manual or automatic retractable assembly Cleanfit CPA472D

Cleanfit CPA472D - Retractable assembly for harsh process conditions ©Endress+Hauser
Cleanfit CPA472D - Detail sensor holder ©Endress+Hauser
Cleanfit CPA472D assembly for harsh process conditions ©Endress+Hauser

Heavy-duty assembly for chemical and power industries

The Cleanfit CPA472D assembly is designed for harsh process conditions. It offers a great variety of rugged materials to operate your sensors safely even under high pressure, high temperature or in aggressive media. The assembly allows you to replace sensors without interrupting the process or to clean and calibrate them automatically via the optional control system. Benefit from easy, time-saving sensor handling and an extended operating life of the sensors.

  • Enkle produkter

  • Enkelt å velge, intallere og bruke

Tekniske egenskaper

Enkelhet

  • Standardprodukter

  • Pålitelige, robuste og lette å vedlikeholde

Tekniske egenskaper

Enkelhet

  • High- end produkter

  • Høyst funksjonelle og praktiske

Tekniske egenskaper

Enkelhet

  • Spesialprodukter

  • Designet for krevende applikasjoner

Tekniske egenskaper

Enkelhet

Varierende

FLEX utvalget Tekniske egenskaper Enkelhet
  • F
  • L
  • E
  • X

Fundamental utvalg

Møter dine grunleggende målebehov

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Lean utvalg

Håndter henkelt dine kjerneprosesser

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Extended utvalg

Optimaliser prosessene dine med innovative teknologier

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Xpert utvalg

Mestre de mest utfordrende applikasjonene dine

Tekniske egenskaper
Enkelhet

Varierende

  • Spesifikasjonene kort oppsummert

    • Process temperature

      0 to 140 °C (32 to 284 °F)

    • Process pressure

      0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
      0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

Hurtigvalg

Velg ett av våre foreslåtte alternative
Sales price
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

eller

individuell konfigurasjon

Fortsett for å velge blant alle mulige alternativer
  • Fordeler

    • Extremely robust: Suitable for use with pressures of up to 10 bar and temperatures of up to 140° C even as PEEK, PVDF, conductive PVDF versions

    • Maximum chemical resistance ensures long operating times

    • No process interruption for electrode cleaning and...

  • Bruksområde

    The Cleanfit CPA472D is intended for installation in tanks or pipes in:

    • Chemical industry

    • Power plants

    • Biodiesel plants

    It is suitable for use with pressures of up to 10 bar.

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Sensor ORP / Redox

  • Application

    Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes

  • Installation

    Retractable holder

  • Characteristic

    For tanks and process vats and pipelines or pipes (min. DN80)
    The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar

  • Design

    Manual or pneumatical

  • Material

    Electrode holder, rinse chamber and raised face:
    PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
    Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)

  • Dimension

    Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)

  • Process temperature

    0 to 140 °C (32 to 284 °F)

  • Process pressure

    0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
    0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

  • Connection

    Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

  • Measuring principle

    Potentiometric

  • Application

    Chemical industry, biodiesel plants, power plants, plant design, tanks, process vats or pipes

  • Installation

    Retractable holder

  • Characteristic

    For tanks and process vats and pipelines or pipes (min. DN80)
    The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar

  • Design

    Manual or pneumatical

  • Material

    Electrode holder, rinse chamber and raised face:
    PEEK, PVDF, conductive PVDF, Alloy C22, stainless steel 1.4571
    Seals: EPDM, FPM (Viton) or FFKM (Kalrez®)

  • Dimension

    Immersion depth: 146 or 280 mm (5.75 or 7.87 inch)

  • Process temperature

    0 to 140 °C (32 to 284 °F)

  • Process pressure

    0 to max. 4 bar (0 to max. 58 psi) overpressure for manual actuation
    0 to 10 bar (0 to 145 psi) overpressure for pneumatic actuation

  • Connection

    Process connections: Flange DN 50, DN 80, ANSI 2", JIS IS10K50A, internal thread G1¼

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification