Manual or automatic retractable assembly Cleanfit CPA472D

Cleanfit CPA472D - Retractable assembly for harsh process conditions ©Endress+Hauser
Cleanfit CPA472D - Detail sensor holder ©Endress+Hauser
Cleanfit CPA472D with sight glass assembly ©Endress+Hauser
Cleanfit CPA472D assembly for harsh process conditions ©Endress+Hauser

Heavy-duty assembly for chemical and power industries

The Cleanfit CPA472D assembly is designed for harsh process conditions. It offers a great variety of rugged materials to operate your sensors safely even under high pressure, high temperature or in aggressive media. The assembly allows you to replace sensors without interrupting the process or to clean and calibrate them automatically via the optional control system. Benefit from easy, time-saving sensor handling and an extended operating life of the sensors.

  • Fordeler

    • Extremely robust: Suitable for use with pressures of up to 10 bar and temperatures of up to 140° C even as PEEK, PVDF, conductive PVDF versions

    • Maximum chemical resistance ensures long operating times

    • No process interruption for electrode cleaning and...

  • Bruksområde

    The Cleanfit CPA472D is intended for installation in tanks or pipes in:

    • Chemical industry

    • Power plants

    • Biodiesel plants

    It is suitable for use with pressures of up to 10 bar.

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Sensor ORP / Redox

  • Application

    chemical industry, power plants, plant design

  • Installation

    retractable holder

  • Characteristic

    For tanks and process vats and pipelines or pipes (min.DN80). The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar.

  • Design

    - manual or pneumatical

  • Material

    holder: PVDF, PVDF-conductive, PEEK, SS 316Ti, hastelloy or titanium sealing: FPM(Viton), FFKM(Kalrez)

  • Dimension

    immerson depth: 148 - 280mm
    ( 5.77inch - 10.92inch)

  • Process temperature

    max.140 °C (284 °F)

  • Process pressure

    max. 4 bar (87 psi) manual drivemax. 10 bar (145 psi) pneumatical drive

  • Connection

    holder: internal thread 1,25", process connection DN50/DN80 , ASME2"

  • Measuring principle

    Sensor ORP / Redox

  • Application

    chemical industry, power plants, plant design

  • Installation

    retractable holder

  • Characteristic

    For tanks and process vats and pipelines or pipes (min.DN80). The robust retractable assembly permits replacement of the electrode while the tank is full or under process conditions with pressures of up to 6 bar.

  • Design

    - manual or pneumatical

  • Material

    holder: PVDF, PVDF-conductive, PEEK, SS 316Ti, hastelloy or titanium sealing: FPM(Viton), FFKM(Kalrez)

  • Dimension

    immerson depth: 148 - 280mm
    ( 5.77inch - 10.92inch)

  • Process temperature

    max.140 °C (284 °F)

  • Process pressure

    max. 4 bar (87 psi) manual drivemax. 10 bar (145 psi) pneumatical drive

  • Connection

    holder: internal thread 1,25", process connection DN50/DN80 , ASME2"

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification