Du må skrive inn minst 2 tegn for å starte søket.

Compact conductivity device
Smartec CLD18

Compact conductivity device
Smartec CLD18 ©Endress+Hauser
Plastic version of the compact conductivity device Smartec CLD18 ©Endress+Hauser

The conductivity of a liquid can be measured using the conductive or toroidal measuring principles. This video shows what it is about and how these measuring principles work.

Toroidal conductivity measuring system for hygienic applications

Smartec CLD18 is the cost-effective solution for all applications in beverage plants where small tubes are used and where the toroidal measurement is used as a switch function. The combination of a transmitter and a sensor is interference-free, easy-to-use and features a hygienic design that protects your products and processes from contamination. Smartec CLD18 ensures the Overall Equipment Effectiveness (OEE) of your plant thanks to fast and reliable CIP and phase separation measurements.

  • Enkle produkter

  • Enkelt å velge, intallere og bruke

Tekniske egenskaper

Enkelhet

  • Standardprodukter

  • Pålitelige, robuste og lette å vedlikeholde

Tekniske egenskaper

Enkelhet

  • High- end produkter

  • Høyst funksjonelle og praktiske

Tekniske egenskaper

Enkelhet

  • Spesialprodukter

  • Designet for krevende applikasjoner

Tekniske egenskaper

Enkelhet

Varierende

FLEX utvalget Tekniske egenskaper Enkelhet
  • F
  • L
  • E
  • X

Fundamental utvalg

Møter dine grunleggende målebehov

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Lean utvalg

Håndter henkelt dine kjerneprosesser

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Extended utvalg

Optimaliser prosessene dine med innovative teknologier

Tekniske egenskaper
Enkelhet
  • F
  • L
  • E
  • X

Xpert utvalg

Mestre de mest utfordrende applikasjonene dine

Tekniske egenskaper
Enkelhet

Varierende

  • Spesifikasjonene kort oppsummert

    • Measurement range

      200 µS/cm to 1000 mS/cm
      Cell constant k: 11.0 1/cm

    • Process temperature

      -10 °C to 110 °C (14 °F to 230 °F)
      Sterilization: max. 130 °C at 6 bar abs up to 60 min
      (Max. 266 °F at 87 psi up to 60 min)

    • Process pressure

      13 bar abs up to 50 °C (188.5 psi up to 122 °F)
      7.75 bar abs at 110 °C (112 psi at 230 °F)
      6.0 bar abs at 130 °C for max. 60 minutes
      (87 psi at 266 °F for max. 60 minutes)

please wait Loading alternative products

Hurtigvalg

Velg ett av våre foreslåtte alternative
Sales price
  • <%label%>
  • <%feature%>
  • Process Connection
  • <%message%>

eller

individuell konfigurasjon

Fortsett for å velge blant alle mulige alternativer
  • Fordeler

    • Unique hygienic design avoids contamination

    • 3-A approval

    • Compliant with EG 2023/2006 and 1935/2004

    • Suitable for cleaning-in-place (CIP)

    • Compact design permits installation in small tubes without restricting the flow

  • Bruksområde

    The hygienic Smartec CLD18 measures toroidal conductivity in beverage applications:

    • Control of CIP processes in the return channel

    • Concentration control in remaking of CIP cleaning agents

    • Product monitoring in pipe systems, bottling plants

    • Beer - Push...

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Inductive

  • Application

    Food and beverage industries

  • Characteristic

    Specifically intended for use in beverage industry applications and especially suitable for:
    Phase separation, control of CIP, concentration control, product monitoring, leakage monitoring

  • Measurement range

    200 µS/cm to 1000 mS/cm
    Cell constant k: 11.0 1/cm

  • Measuring principle

    Inductive conductivity measurement

  • Design

    Hygienic design with FDA certified virgin PEEK

  • Material

    Sensor: PEEK
    Process connection 1.4435 (316L)
    Seal: EPDM

  • Process temperature

    -10 °C to 110 °C (14 °F to 230 °F)
    Sterilization: max. 130 °C at 6 bar abs up to 60 min
    (Max. 266 °F at 87 psi up to 60 min)

  • Process pressure

    13 bar abs up to 50 °C (188.5 psi up to 122 °F)

    7.75 bar abs at 110 °C (112 psi at 230 °F)

    6.0 bar abs at 130 °C for max. 60 minutes
    (87 psi at 266 °F for max. 60 minutes)

  • Temperature sensor

    Pt 1000 (class B)

  • Connection

    Dairy pipe, aseptic-fitting DN40 and DN50, Clamp 2"
    ISO 2852, SMS-2", Varivent N DN 40-125
    Thread G1 1/2 SS, G1 1/2 PVC , Union nut 2 1/4 Inch PVC

  • Ingres protection

    IP69

  • Output / communication

    0/4...20mA
    IO-Link (option)

  • Additional certifications

    3A, FDA, EHEDG
    EC Regulation No. 1935/2004

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification
    • Order code 71228583

      Kit CLD18 Housing upper part plastic

    • Order code 71228584

      Kit CLD18 Housing upper part st. steel

    • Order code 50081902

      Calibration solution CLY11-A, 74,0 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081903

      Calibration solution CLY11-B,149,6 uS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO.

    • Order code 50081904

      Calibration solution CLY11-C,1,406mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081905

      Calibration solution CLY11-D,12,64 mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM to NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO

    • Order code 50081906

      Calibration solution CLY11-E,107,00mS/cm

      500 ml, reference temperature 25oC. Precision solution referred to SRM of NIST. With temp. table for qualified calibration of conductivity measuring systems acc. to ISO