Ammonium analyzer
Liquiline System CA80AM

Liquiline System CA80AM - High-precision process analyzer for ammonium measurement ©Endress+Hauser
Liquiline System CA80AM ammonium analyzer with cooling for extended reagent lifetime ©Endress+Hauser
Liquiline System CA80AM ammonium analyzer - Cost-efficient version without cooling ©Endress+Hauser
Sample collector with level detection for the monitoring of sample transport ©Endress+Hauser

Ammonium concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.

Colorimetric system for online monitoring of water and wastewater treatment

Liquiline System CA80AM offers high-precision ammonium measurement in all critical control points. As member of the Liquiline platform, it enables plug & play and easy upgrade to a measuring station - minimizing the installation effort. Automatic calibration and cleaning as well as the low consumption of reagents save you operating and maintenance costs. Advanced diagnostics with remote access ensure process safety and support you in providing process documentation to the authorities.

  • Fordeler

    • Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation

    • Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors

    • Advanced diagnostics with remote...

  • Bruksområde

    Liquiline System CA80AM monitors and controls:

    • Inlets of wastewater treatment plants

    • Outlets of wastewater treatment plants for documentation purposes

    • Aeration basins

    • Water treatment

    • Cleaning capacity of municipal and industrial wastewater plants

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Colorimetric

  • Characteristic

    Analyzer for ammonium in aqueous solutions

  • Measuring method

    Comply with standard colorimetric measuring principle - indophenol blue method following ISO 7150-1, DIN 38406-5 and GB 7481-87

  • Size

    Cabinet

    793 x 530 x 417 mm

    31.22 x 20.87 x 16.42 in

    Stand housing

    1693 x 530 x 417 mm

    66.65 x 20.87 x 16.42 in

  • Design

    Open design / cabinet
    Plastic ASA-PC
    Stand housing
    Plastic ASA-PC, steel coated

  • Process temperature

    4 to 40 °C (39 to 104 °F)

  • Ambient temperature

    5 to 40 °C (41 to 104 °F)

  • Process pressure

    unpressurized

  • Sample flow rate

    min. 5 ml/min (0.17 fl.oz/min)

  • Consistency of the sample

    Low solids content

    Turbitity < 50 NTU, aqueous, homogenized

  • Specials

    Easy upgrade to measuring station with up to four digital Memosens sensors

    Automatic calibration and cleaning

    User-configurable measuring, cleaning and calibration intervals

    Optional cooling module for longer reagent life time

    Automatic calibration and cleaning

    Optional 2 channel version

    User-definable measuring ranges

    Flexibale functionality and modular expandable

    Digital communication for remote access

  • Application

    Monitoring and optimization of the cleaning capacity of municipal and industrial wastewater treatment plants

    Monitoring of the wastewater treatment plant outlet for documentation purposes

    Monitoring and optimization of activated sludge basins

  • Power supply

    100 to 120 VAC / 200 to 240 VAC ± 10%

    24 VDC ± 10%

    50 ± 1 or 60 ± 1.2 Hz

  • Output

    2x 0/4 to 20 mA

    Optional: Webserver, Modbus, Ethernet/IP, Profibus DP

  • Input

    1 or 2 measuring channels

    Optinonal 1 to 4 digital sensor inputs for sensors with Memosens protocol

  • Measurement range

    0.05 to 20 mg/l NH4-N

    0.5 to 50 mg/l NH4-N

    1 to 100 mg/l NH4-N

  • Consumables

    Reagents and standard solutions CY80AM

    Cleaner CY800

    Maintenance kit CAV800.

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification