Proline Promag D 400
Electromagnetic flowmeter

Electromagnetic flowmeter - Proline Promag D 400 ©Endress+Hauser

The Electromagnetic Flow Measuring Principle

Introduction of Proline Web server

Meter designed as compact wafer version with a state-of-the-art transmitter for Water & Wastewater

The wafer flowmeter Promag D is designed for all basic water applications where space is at a minimum. Its innovative housing construction enables a customized and fast centering as well as a cost-optimized installation. Promag D 400 saves time and costs thanks to the broad functionality of its water- and wastewater-optimized transmitter. In addition, Heartbeat Technology ensures compliance and process safety at all times.

  • Fordeler

    • Easy, fast centering of the sensor – innovative housing construction

    • Energy-saving flow measurement – no pressure loss due to cross-section constriction

    • Maintenance-free – no moving parts

    • Safe operation – no need to open the device due to display with...

  • Bruksområde

    • The bidirectionally measuring principle is virtually independent of pressure, density, temperature and viscosity

    • For basic water applications; optimized for limited space and plastic pipe installations

    Device properties

    • Short installation length and...

Funksjoner og spesifikasjoner

Tilbake

Details

  • Measuring principle

    Electromagnetic

  • Product headline

    Flowmeter designed as compact wafer version with a state‐of‐the‐art transmitter for Water & Wastewater. For basic water applications; optimized for limited space and plastic pipe installations.

  • Sensor features

    Easy, fast centering of the sensor – innovative housing construction. Energy‐saving flow measurement – no pressure loss due to crosssection constriction. Maintenance‐free – no moving parts. Short installation length and low weight. Integrated ground disks made of stainless steel.

  • Transmitter features

    Safe operation – no need to open the device due to display with touch control, background lighting. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. WLAN access.

  • Nominal diameter range

    DN 25...100
    1"...4"

  • Wetted materials

    Liner: Polyamide
    Electrodes: 1.4435 (316L)

  • Measured variables

    Volume flow, mass flow

  • Max. measurement error

    Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s)

  • Measuring range

    9 to 4700 dm³/min (2.5 to 1250 gal/min)

  • Max. process pressure

    PN 16, Class 150, 10K

  • Medium temperature range

    0 to +60 °C (+32 to +140 °F)

  • Ambient temperature range

    –20 to +60 °C (–4 to +140 °F)

  • Sensor housing material

    AlSi10Mg, coated
    Sensor connection housing: AlSi10Mg, coated

  • Transmitter housing material

    Polycarbonat; AlSi10Mg, coated

  • Degree of protection

    Compact version: IP66/67, type 4X enclosure
    Sensor remote version: IP66/67, type 4X enclosure
    Transmitter remote version: IP66/67, Type 4X enclosure

  • Display/Operation

    4‐line backlit display with touch control (operation from outside)
    Configuration via local display, web browser and operating tools possible

  • Outputs

    3 ouputs:
    0‐20 mA/4‐20 mA HART (active)
    Pulse/frequency/switch output (passive)
    Pulse/frequency output (passive)
    Switch output (passive)

  • Inputs

    Status input

  • Digital communication

    HART, PROFIBUS DP, EtherNet/IP, Modbus RS485

  • Power supply

    AC 100 to 240 V / AC/DC 24 V

  • Hazardous area approvals

    cCSAus

  • Product safety

    CE, C-tick, EAC marking

  • Metrological approvals and certificates

    Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR

  • Pressure approvals and certificates

    CRN

  • Hygienic approvals and certificates

    ACS, KTW/W270, NSF 61, WRAS BS 6920

Dokumenter / håndbøker / programvare

Tilbehør / reservedeler

Nr
Order code
Specification
  • 45
    • Nr 45 Order code 71228789

      Kit connection terminals, Promag 400(C)

      (C) = generation index C. Consists of: Connection terminal 3-Pol stamp 1,2, Connection terminal 2-Pol stamp A,B, Connection terminal 4-Pol stamp 20-23, Connection terminal 4-Pol stamp 24-26.

  • 40
    • Nr 40 Order code 71228791

      Kit connec. board, D, compact, electr.

      Usage: Promag 400(C) with sensor D. (C) = generation index C.

    • Nr 40 Order code 71228790

      Kit connec. board, D/L/W, remote,electr.

      Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C.

  • 30
    • Nr 30 Order code XPD0014-

      Electronic Promag 400 Index C

      Complete main electronic module or power supply, I/O-board and amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection/ Amplifier incl. ribbon cable.

  • 44
  • 39
    • Nr 39 Order code 71185788

      Kit T-DAT, 100/300/400/500/500 digital

      Usage: Promag/Promass 100/300/500, 500 digital, Prosonic Flow E 100, Promag 400(C). (C) = generation index C.

  • 30
    • Nr 30 Order code XPD0040-

      Electronic Promag 400 Index C update

      Complete main electronic module or power supply, I/O-board with amplifier as individual boards. Complete main electronic module contains: Power supply, I/O-board, amplifier, board carrier, terminal connection, ribbon cable, installation marterial. Individual boards contains: Installation marterial, Power supply incl. terminal connection/ I/O-board incl. terminal connection and Amplifier incl. ribbon cable.

  • 50
  • 20
    • Nr 20 Order code 71228788

      Kit cover, polycarbonate, Promag 400(C)

      (C) = generation index C. Consists of: Cover plastic complete, O-Ring 196,44x3,53 VMQ, 2x hinge pin L= 58mm plastic.

    • Nr 20 Order code 71384170

      Kit cover, alu,Promag 400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass 500 digital, transmitter housing Alu. Consists of: cover Alu complete included O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF, wire with screw lock 1,5x150.

  • 24
    • Nr 24 Order code 50094038

      Kit Cover Connection terminal

      10/5X/40/8X/93/65/400/800

    • Nr 24 Order code 71247838

      Repair kit cover, remote version

      Usage: 10/5X/8X/8DF/8CN/92F/65/400/800 acc. service info SI01351D-1/06 Consists of: Cover Rep.kit for G14, O-Ring 110.00 x 4.50 HNBR, Grease

  • 25
    • Nr 25 Order code 71278077

      Kit 10 cover gasket, polycarbonate

      Usage: Promag 400(C), 500 digital with polycarbonate housing. (C) = generation index C. Consists of: 10x O-Ring 196,44x3,53 VMQ.

    • Nr 25 Order code 71278078

      Kit cover gasket, alu,400(C),500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass 500 digital, transmitter housing Alu, Ex. Consists of: 10x O-Ring 196,44x3,53 VMQ, default and -50oC/-58oF.

  • 71
    • Nr 71 Order code 71228793

      Kit housing gasket, D/L/W,compact,400(C)

      Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: Gasket EPDM for housing/sensor D/L/W. O-Ring 29,87x1,78 HNBR for sensor- plug L/W.

  • 73
    • Nr 73 Order code 50098023

      Kit housing gasket FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/L/P/S/W

  • 12
    • Nr 12 Order code 71228794

      Kit housing parts, D/L/W, compact,400(C)

      Usage: Promag 400(C) with sensor D/L/W. (C) = generation index C. Consists of: 4x screw M5x18 hex cap DIN912 pla, 4x spring washer M5 DIN7980 st.pla, for housing/sensor.

  • 13
    • Nr 13 Order code 50098019

      Kit parts housing FS Stnd/HT

      Usage: 10/50/51/53/55/400/800 Sensor: D/E/H/L/P/S/W

  • 15
  • 17
  • 15
  • 17
  • 15
  • 17
  • 15
  • 82
    • Nr 82 Order code 71228792

      Kit display protec., 400(C)/500 digital

      Usage: Promag 400(C) = generation index C, Promag/Promass 500 digital, transmitter housing. Consists of: display protection 1.4301, installation material.

    • Order code 5X4CXX-

      Transmitter/Conversion Kit Promag 400

      Same housing for compact/remote version. Corrosion-resistant transmitter version. With an integrated web server Conversion kit: For conversion of an already existing Promag to the new device generation or to another device version. Consists of all required conversion parts.

    • Order code DK5005-

      Transmitter 400, mounting kit

    • Order code DK5CA-

      Promag, cable remote version

      10/50/51/53/55/400/800 1 kit includes 1 coil cable and 1 signal cable

    • Order code DK5DD-

      Promag D, seal set

      A set includes 2 flange seals

    • Order code DKD-

      Promag D, mounting set

      The mounting set contains threaded bolts, centering sleeves, nuts, washers and a pair of EPDM flange seals orderable separately, as replacement for M1, M2

    • Order code XPRFID-

      Spare RFID TAG

      Consists of: RFID TAG, fixing wire, crimp sleeve.