Endress+Hauser-gruppen

Mediesenter

Events

Din karriere hos Endress+Hauser.

Støtte nær deg

Online Shop

Skriv inn din personlige påloggingsinformasjon for å få tilgang til Online shoppen og legge inn din bestilling, 24 timer i døgnet, hver dag. Du kan også sjekke produktpriser og leveringstider, eller be om et pristilbud.

Online Shop

E-direct Shop

E-direkte: Bestill pre-konfigurerte instrumenter og systemkomponenter raskt og enkelt online.

E-direct Shop

Vibronic
Point level detection
Nivotester FailSafe FTL825

Point level switching unit for Liquiphant FailSafe FTL80, FTL81 and FTL85

  • Nivotester FTL825 FailSafe ©Endress+Hauser

The Nivotester FTL825 supplies the Liquiphant FailSafe FTL8x point level switch with direct voltage via a two-wire cable. At the same time, it analyzes the current values (4-20mA discrete) of the Liquiphant and returns a switching signal. The signal inputs of the Nivotester FTL825 are galvanically isolated from the mains and the output and can be ordered Safety-critical systems up to SIL3. For industries where redundant or diverse systems are either not recommended or not possible.

Fordeler

  • Use in safety systems requiring functional safety to SIL3 in accordance with
    IEC 61508 Ed.2.0 /IEC 61511-1 / ISA 84-1

  • Proof test: proof testing interval up to 12 years, Slave devices tested at the press of a button

  • For safety-critical systems up to SIL3 in the chemicals, petrochemicals and oil & gas industries

  • For applications where redundant or diverse systems are either not recommended or not possible, the longest possible test cycles are desirable, or proof tests are either not possible or only with great difficulty and expense

  • Integrated locking function (self-holding)

  • 4 switching outputs (can be analyzed separately): 2 as level safety contacts based on the quiescent current principle for a redundant output signal, 1 x signaling contact (e.g. lamp),
    1 x fault-signaling contact as changeover contact

Bruksområde

FailSafe point level switch unit for top hat rail mounting.

  • Ambient temperature: -20 to +60°C (-4 to +140°F)

  • International explosion protection certificates, overfill prevention WHG

Funksjoner og spesifikasjoner

Dokumenter/håndbøker/programvare

Tilbehør/reservedeler

Kontakt

Endress+Hauser AS
Postboks 62 3421 Lierskogen , Norge
Tlf.: +47 32 85 98 50
Faks: +47 32 85 98 51
Send e-post www.no.endress.com

Relaterte nyheter

Nettverktøy