RIA15
Loop-powered indicator for 4…20 mA or HART® signals

For the indication of the 4…20 mA signal or the HART® values in the field or in the panel!

  • Loop-powered indicator RIA15 ©Endress+Hauser
  • Loop-powered indicator RIA15 ©Endress+Hauser
  • Product video process display RIA15 with HART communication

The process indicator is available with 4...20 mA or with HART® protocol. In the HART® version up to 4 measured values of one sensor can be indicated in alternation. For this the indicator can be set as primary or secondary HART® master and actively inquire the values from the sensor. The small voltage drop of < 1V (< 1.9 V with HART®) is a huge advantage especially in Ex-applications, where in most cases only a reduced voltage is available.

Fordeler

  • Display of 4 to 20 mA measured values or optionally up to four of a sensor's HART® process variables in all industries; Use as primary or secondary HART® master

  • 5-digit measured value display with 17 mm (0.67") character height with dimension and bargraph; backlight can be activated

  • Panel-mount housing (IP65) or field housing (IP66; Ex approval) as local display; Minimal installation depth

  • No external power supply required; Voltage drop ≤1 V (HART® ≤1.9 V)

  • Easy 3-key operation for configuring the device

  • International approvals

  • SIL interference freeness acc. to EN 60508

Bruksområde

  • Display of 4 to 20 mA measured values or HART® process variables in all industries

  • Panel-mount housing or field housing as local display

  • Scalable display value

  • The RIA15 can be used to make the basic settings of the Micropilot FMR20. For this, the RIA15 must be ordered with the corresponding option "FMR20 basic setting".

Funksjoner og spesifikasjoner

Dokumenter/håndbøker/programvare

Tilbehør/reservedeler

Forgjenger / Erstatter

Forgjenger: Process indicator RIA251, Field indicator RIA261, VU2550, VU2551